Liquid Solutions
Hamilton is one of the few sensor providers to make all of our own liquid calibration standards, buffers, and electrolytes in-house. These products are specifically designed to work with our sensor products lines and ensure the highest quality measurement along with full traceability of the reference material during future calibration or maintenance work.
Cell Density Solutions
Liquid validation and calibration standards for setup and verification of Incyte and Dencytee cell density products.

DuraCal pH Buffers
Patented buffer solutions provide pH stability of up to five years. High buffering capacity provides rapid and stable calibration.
DuraCal ORP Buffers
Hamilton ORP buffers are stable for two years. You can always rely on them even if they have been used.
Conductivity Standards
Stability from 1 to 3 years respectively and conductivity ranges from 1.3 µS/cm to 100 mS/cm
Resources
Hamilton's knowledge base provides a range of explanatory articles, frequently asked questions, and document downloads.
-
Catalog - Process Analytics
Download the Process Analytics sensor catalog to learn about the complete offering of Hamilton process sensors and accessories. -
Brochure - BioPharma
Innovative solutions for process analytics in biotechnological and pharmaceutical industries.
-
How often do Incyte sensors (pre-amp version) need to be calibrated?
Hamilton recommends once per year with a validation at 6 months. -
Which liquid conductivity standard should I use for calibration?
A conductivity standard should be chosen that most closely matches the anticipated conductivity range of the process. -
What can I use to clean the conductivity sensor electrodes if fouling occurs?
The metal electrodes of 2 and 4-pole sensors can be cleaned with water and mild detergents and washed with deionized water after cleaning. Care should be taken to not use cleaning agents that can impact the material of the electrodes. Click to reference the knowledgebase article on cleaning for more information.
-
Temperature Influence on Conductivity Standards
Temperature has a direct effect on the conductivity of liquid standards. This page lists the temperature effects on all Hamilton standards in one easy to use place. -
Stability and Accuracy of Conductivity Standards
Questions often come up regarding liquid conductivity standards and how these products should be used. This knowledgebase article takes on many of these topics. -
Documentation and Certificates for Sensors and Liquid Solutions
What documentation and certificates can I expect with my sensor or probe? This article provides examples of the types of paper documents that normally come with Hamilton products.

We're Ready to Help
Hamilton's sales, customer service, and technical support staff are available for questions and additional information about all products and services.
Contact Us